Panel Meter
General Features
Standards
-
CE CERTIFICATE IEC414 IEC51
Cases
-
ABS & PC Material.
Protection degree (CEI 70-1, IEC 529) IP52 for the case.
Protection degree (CEI 70-1, IEC 529) IP00 for terminals.
Accuracy Class
-
Alt the instruments are manufactured in 1.0 1.5 2.5 accuracy class (if no special indications).
The precision for reduced scale instuments (F2-F3-F5) will be<20%, with stop time <2 second.
Overloads
-
All amperometry circuits support an overloadof 1.2 in continuous and 10 in during 5 seconds.
Working Voltage: 650V
-
Test voltage: 2000V-50Hz/60Hz, for 1 minute
Insulation:
-
Insulation reference voltage 0.6KV.Working temperature20°C(±10°C)working range between -25°C ~ +55°C
Vibrations
-
±0.25mm amplitude at 50Hz/60Hz(CE68-2-6).
Humidity
-
Ambient relative humidity 85% without condensing, with 35°C tem-perature for max. 60 days per year.Yearly average humidity must benot higher than 65%(DIN 40040).
Tropical Version
-
95% relative humidity.for a maximum of 30 days per year.
Mounting Position
-
The normal execution of our instruments is for vertical mounting.theother mounting positions are known in advance, please indicate theangle of inclination when ordering.
Scales
-
The full scale deflections correspond to DIN 4371.
The scale divisions correspond to DIN 43802.
Special Excution
- Tropical version
- Red stroke at any point on the scale
- Red stripe on the scale
- Additional lettering
- Anti-refiection glass
- Internal illumination (when possible)
- Test voltage higher than 2000V
- Knife edge pointer and scale with mirror reading
- Red pointer adjustable from the exterior
- Scale for other rangesscale with double numbering
- Scale with double sats of numbering divisions.
- Scale with zero point in the middle or displaced
- Range differing from standard series
- Two/three/four range voltmetersTwo range ammeters(3 terminals)
- Adjustment to other internal resistance for am-metersInternal resistance for voltmeters from 1 to 600V: 1000Ω/V, 4000Ω/V, 10000Ω/V, 20000Ω/V
- Separate resistorbox for 1000V and 1500V
- Suppressed zero
- Accuracy class 1
- Potentiometer adjustable from the exterior (20% FSD)
- Range for voltmeters differing form standard series
- Range for ammeters differing form standard serieies
- Ammeters with 2 in-3 in-5 in overload capacity
- Two range voltmeters (3 terminal)
- Two range ammeters (3 terminal) (max 10A)
- Calibration for A.C and D.C. (max. 50A)
- Separate resistance for 1000V and 1500V
- Accuracy class 1 (only 50-60 Hz)
- Scale with zero point in the middle or displaced
- Nominal current 5A (per element)
- Double-triple voltage
- Double current
- Non-standard voltage
- Non-standard voltage
- Double volage (when possible)
General features:
Moving Coil Instruments
Moving Iron Voltmeters and Ammeters Calibration for Other Ranges
Wattmeters
Power Factor Meter
Reed Frequency Meters
Symbole of the main measuring units and the prin-cipals multiples and submultipes
Symbols | Description |
Electronic device in a measure circuit | |
Rectifier(instrument with A.C. input). | |
Shunt | |
Additional resistor | |
Zero setting device(of the field measure amplitude) | |
General accessories | |
Ground terminal | |
Positive terminal | |
Negative terminal | |
1.0 1.5 2.5 | Class index(for ex.1)except when the conventional value corresponds to the scale length or to the indicated value or to measure range |
D.C.circuit and/or measure mark which corresponds to D.C. | |
A.C.circuit and/or measure mark which corresponds to A.C. | |
D.C. and/or A.C.circuit and /or measure mark which corresponds to D.C.and to A.C. | |
Testing voltage higher than 500V(for example 2kV) | |
Instrument to be used with vertical scale | |
Instrument to be used with scale inclined compared to the horizontal(for example 60°)-on request | |
Moving coil for D.C. instruments | |
Moving iron instrument for A.C. instruments | |
Bimetal instrument | |
Vibrating reeds instrument |
Outline and Mounting Dimensions
Model | A | B | C | D | E | F |
96X96 | 96 | 92 | 90 | 5.5 | 65 | 43 |
72X72 | 72 | 68 | 66 | 5.5 | 65 | 43 |
48X48 | 48 | 44 | 42 | 5.5 | 65 | 43 |