Fan & Fan Filter

Fan & Fan Filter

Home

FK55

Application

    Extra-thin ventilation filter edge adding the high-grade fluid sealant can prevent the rainwater entering the control cabinet along the filter from the holing place. Especially the surface leaf bar, with the arc structure, can prevent the rainwater entering, Adhesive bonded fiber filter pad can be used to prevent over 10 microns dust granule. Extra-thin leaf bar thickness bulges only 4~6mm, which largely raises its beautiful degree. Installation need not screw, only inlay. Its protection grade can reach IP54.

Technical Data

FK5522FK5522
Fand Filter Type FK 5522.230 5522.115 5522.024
Working Voltage V/H 230/50/60 115/50/60 24(DC)
Air flow, free blowing 55/66m3/h
Flux of air equip filter exproted include filtering pad of standard 1xFK 5522.300; 43/50m3/h
2xFK 5522.300; 48/55m3/h
1xFK 5522.300; 48/55m3/h
Axial Fan Self-start screened magnetic pole motor Direct current motor
Rated Current 0.12/0.11A 0.24/0.23A 0.15A
Power 19W/18W 3.5W
Noise level 46/49dB(A)
Scope of temperature -10°C ~ 55°C
Exit Filter Type FK 5522.300

Dimensioned

Dimensioned Dimensioned
Dimensioned Dimensioned
Dimensioned Dimensioned
Dimensioned Dimensioned
Dimensioned Dimensioned
FK5522.230
Dimensioned
Dimensioned
Dimensioned
Dimensioned
Dimensioned
FK5522.300
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Head
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Installation
FK5523FK5523
Fand Filter Type FK 5523.230 5523.115 5523.024
Working Voltage V/H 230/50/60 115/50/60 24(DC)
Air flow, free blowing 105/120m3/h
Flux of air equip filter exproted include filtering pad of standard 1xFK 5523.200; 71/82m3/h
2xFK 5523.200; 85/98m3/h
1xFK 5523.200; 78/90m3/h
Axial Fan Self-start screened magnetic pole motor Direct current motor
Rated Current 0.12/0.11A 0.24/0.23A 0.15A
Power 19W/18W 3.5W
Noise level 46/49dB(A)
Scope of temperature -10°C ~ 55°C
Exit Filter Type FK 5523.300

Dimensioned

Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
FK5523.230
Dimensioned
Dimensioned
Dimensioned
Dimensioned
Dimensioned
FK5523.300
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Head
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Installation
FK5525FK5525
Fand Filter Type FK 5525.230 5525.115 5525.024
Working Voltage V/H 230/50/60 115/50/60 24(DC)
Air flow, free blowing 230/265m3/h
Flux of air equip filter exproted include filtering pad of standard 1xFK 5525.200; 170/205m3/h
2xFK 5525.200; 200/230m3/h
1xFK 5525.200; 190/215m3/h
Axial Fan Self-start screened magnetic pole motor Direct current motor
Rated Current 0.28/0.24A 0.53/0.49A 0.58A
Power 41W/38W 14W
Noise level 54/56dB(A)
Scope of temperature -10°C ~ 55°C
Exit Filter Type FK 5525.300

Dimensioned

Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
FK5525.230
Dimensioned
Dimensioned
Dimensioned
Dimensioned
Dimensioned
FK5525.300
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Head
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Installation
FK5526FK5526
Fand Filter Type FK 5526.230 5526.115
Working Voltage V/H 230/50/60 115/50/60
Air flow, free blowing 500/560m3/h
Flux of air equip filter exproted include filtering pad of standard 1xFK 5526.200; 360/390m3/h
2xFK 5526.200; 440/495m3/h
Axial Fan Capacitance electromotion
Rated Current 0.29/0.35A 0.58/0.70A
Power 64W/80W
Noise level 59/61dB(A)
Scope of temperature -10°C ~ 55°C
Exit Filter Type FK 5526.300

Dimensioned

Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned
FK5526.230
Dimensioned
Dimensioned
Dimensioned
Dimensioned
Dimensioned
FK5526.300
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Head
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Dimensioned Dimensioned Dimensioned Dimensioned
Installation

Top

Disclaimer: The appearance of the products listed on this website, color, parameters are for reference only, issued a kind of LANGIR Electric Company shall prevail.
LANGIR Electric Company reserves the right to modify or cancel the relevant parameters of this website does not advance notice. If in doubt, please contact customer service hotline.